Transcript
INTER-OFFICE MEMORANDUM Page 1 County of Henrico Building Inspections Department, Virginia INTER-OFFICE MEMORANDUM Residential Wood Deck Stair Stringer Attachment Details Below are acceptable residential wood deck stair stringer attachment details approved by the Henrico County Building Inspections Department. Other alternate means of attachment may be acceptable but must be s,ubmitted to the individual county plan reviewer for approval. Stair stringer attachment details shall be attached to the building permit application for approval. cut post at bottom tread elevation when no stair guard is required 11," diameter thru-bolt stair stringer w/nut and washer (no carriage bolts) 12" square or round x 4" thick pier block or ____ poured concrete footing ~ frost de th Stair Stringer Bearing At Grade End joist with blocking Back to next joist ----""\ Joist hanger maybe a: 1. Simpson LSU26 or A35 2. USP LS268 or MPAI ----' • Stair Stringer Attachment Detail I OF 2 Page 2 '12" diameter thru-bolt w/nut and washer (no carriage bolts) Deck joist 2x6 connector at each stringer with 4 - 10d nails. and a '12" galvanized thru bolt with washers. connect stringer to spacer with with A35 or MPAI hanger Stair Stringer Attachment Detail 20f2
Original URL
http://www.co.henrico.va.us/bldg/pdfs/Deck_Stairs.pdf